Analysis of the Individual Support Capacity of Pile Foundations Using a Pile Driving Analyzer Test Control Instrument: A Case Study of the SPK CSA Building Tower Plan 3A in Sidoarjo- Surabaya
Abstract
Foundations play a crucial role in the stability of structures. The 8-story CSA Tower SPK Building Plan 3A project uses pile foundations to support the load from the top of the structure to the soil layer beneath the building. Pile foundations must undergo testing to demonstrate their ability to bear load. This study analyzes the ultimate bearing capacity through a comparative analytical approach between the dynamic Pile Driving Analyzer Test (PDA) method and advanced analysis using CAPWAP (Case Pile Wave Analysis Program) with a numerical analysis method by evaluating the bearing capacity based on force and velocity wave data from the PDA Test to simulate static load tests and predict load displacement behavior. The results of the study show that the maximum energy transfer (EMX) for the three different pile foundations, each with a pile number of T-174, is 5.60 tons.m, pile number T-317 of 4.37 ton.m, and pile number GT-31 of 5.60 ton.m, all tested with a Drop Hammer type weighing ± 4.00 tons at a height range of 1.5-2 m. Further CAPWAP analysis results showed an average bearing capacity of 238.70 tons, which is 5.34% lower than the PDA result of 249.67 tons. The difference is due to more precise mathematical corrections in CAPWAP through signal matching analysis. Based on the maximum settlement standard of 25 mm, the maximum settlement in this study was 15.92 mm, with values below the maximum confirming the reliability of the foundation design. The PDA Test results showed the ultimate bearing capacity of the pile foundation.
Keywords
Full Text:
PDFReferences
I. Mohamad Badrudin, “Pengaruh Kapasitas Daya Dukung terhadap Letak Fondasi Dangkal Tipe Menerus di Sepanjang Lereng dengan Menggunakan Metode Analitik dan Numerik.,†RekaRacana J. Tek. Sipil, vol. 4, no. 2, pp. 113–124, 2018, doi: 10.26760/rekaracana.v4i2.113.
L. E. fatmawati Reny Pradista, “Analisis Perbandingan Kapasitas Dukung Tiang Pancang Tunggal Berdasarkan Data SPT dan PDA,†Musamus J. Civ. Eng., vol. 6, no. 01, pp. 1–7, 2024, doi: 10.35724/mjce.v6i01.5727.
A. Yusti and F. Fahriani, “Analisa Daya Dukung Pondasi Tiang Pancang Diverifikasi Dengan HAsil Uji Pile Driving ANalyzer Test Dan CAPWAP (Studi Kasus Proyek Pembangunan Gedung Kantor Bank Sumsel Babel di Pangkalpinang),†J. Forum Prof. Tek. Sipil, vol. 2, no. 1, pp. 19–31, 2014, [Online]. Available: https://www.neliti.com/publications/61239/analisis-daya-dukung-pondasi-tiang-pancang-diverifikasi-dengan-hasil-uji-pile-dr
F. M. Munirwansyah, Reza P. Munirwan, “Analisis Daya Dukung Axial Pondasi Tiang Pancang Dengan Menggunakan Metode Kalendering Hasil Uji Pile Driving Analyzer,†Teras J. J. Tek. Sipil, vol. 12, no. 1, p. 93, 2022, doi: 10.29103/tj.v12i1.618.
M. Zulfiqar and M. Hudori, “Studi Komparatif Daya Dukung Pondasi Tiang Pancang Berdasarkan Hasil Pile Driving Analyzer Test dan N-SPT,†J. Talent. Sipil, vol. 6, no. 2, p. 229, 2023, doi: 10.33087/talentasipil.v6i2.259.
I. W. A. P. P. Tjokorda Istri Praganingrum, Anak Agung Ratu Ritaka Wangsa, Ni Luh Made Ayu Mirayani Pradnyadari, “Analisis Perbandingan Pengujian Bore Pile Menggunakan Slt (Static Loading Test) Dengan Pda (Pile Driving Analyzer) (Studi Kasus: Proyek Tsinghua Kampus, Serangan Denpasar),†Ganec Swara, vol. 18, no. 2, p. 925, 2024, doi: 10.35327/gara.v18i2.879.
E. Raudhati, “Analisis Daya Dukung Pondasi Tiang Menggunakan Metode Pile Driving Analyzer ( PDA ) ( Studi Kasus : Jembatan Rengas , Kabupaten Batang Hari ),†J. iImiah Univ. Batanghari Jambi, vol. 25, no. 1, pp. 930–935, 2025, doi: 10.33087/jiubj.v25i1.6049.
H. Hasrullah, S. Iswandi, and D. Novianto, “Analisis Daya Dukung Dan Penurunan Tiang Pancang Menggunakan Data Pda Test Dan Program Plaxis Pada Pembangunan Gedung Laboratorium Dan Kuliah Terpadu Universitas Borneo Tarakan,†J. Qua Tek., vol. 11, no. 2, pp. 90–102, 2021, doi: 10.35457/quateknika.v11i2.1704.
A. Omarov et al., “Bearing Capacity of Precast Concrete Joint Micropile Foundations in Embedded Layers: Predictions from Dynamic and Static Load Tests according to ASTM Standards,†Infrastructures, vol. 9, no. 7, 2024, doi: 10.3390/infrastructures9070104.
Rasdinanta Tarigan, “Komparasi Kinerja Alat Pile Driving Analyzer Dan Software Capwap Dalam Menghasilkan Daya Dukung Ultimit Pondasi Tiang,†J. Darma Agung, vol. 28, no. 3, pp. 378–386, 2020, doi: 10.46930/ojsuda.v28i3.802.
D. Yogaswara and R. Riyantini, “Analisis Pengendalian Mutu Fondasi Tiang Bor Berdasarkan Uji PDA dan Uji PIT,†vol. 21, no. 1, pp. 32–47, 2025, doi: 10.28932/jts.v21i1.7345.
ASTM D4945, “Standard Test Method for High-Strain Dynamic Testing of Deep Foundations,†Annu. B. ASTM Stand., vol. i, pp. 1–10, 2012.
SNI 8459:2017, “Metode uji fondasi dalam dengan High-Strain Dynamic Pile ( HSDP ) Standard Test Method for High-Strain Dynamic Testing of Deep Foundations,†Badan Stand. Nas., 2017.
D4945-17, “Standard Test Method for High-Strain Dynamic Testing of Deep Foundations1,†AnnAual B. ASTM Stand., vol. i, no. Reapproved, pp. 3–5, 2017, doi: 10.1520/D4945-17.2.
H. T. Santoso and J. Hartono, “Analisis Perbandingan Daya Dukung Pondasi Tiang Pancang Berdasar Hasil Uji Spt Dan Pengujian Dinamis,†J. Ris. Rekayasa Sipil, vol. 4, no. 1, p. 30, 2020, doi: 10.20961/jrrs.v4i1.44635.
Refbacks
- There are currently no refbacks.